LIBERTY® Series 2000 VRLA Battery
Dependability...Inside
and Out.
We
have taken the top-rated, most dependable VRLA battery
available and added the latest technology to create the
Liberty 2000 MAX ™. You get maximum back-up
performance and reliability whether you are supporting a
cell site, central office, uninterruptible power system,
switchgear or Internet server applications.
The Liberty 2000 MAX is the result of years of research in
refining the best VRLA battery system on the market. Our
numerous patents provide longer life and reduced
maintenance. This translates to a lower life cycle cost,
while ensuring maximum back-up power when you need it.
Measurable quality.
Outstanding performance.
-
Consistent float voltage +/-.050 Vpc
-
On average, 100 percent system capacity at time of
shipment.
-
1200 cycles to 80 percent depth of discharge at 8-hour
rate to 1.75 Vpc at 77F
-
20-year design life at 77F (25C) full float service
Discover the newest VRLA technology for yourself.
For
more information on the Liberty 2000 MAX, or to speak with
a sales representative, please call us at (800) 543-8630
or your local C&D Representative. You can also e-mail us
at powercom@cdtechno.com. Visit us on the Internet at
www.cdpowercom.com.

Insulated
Plate Boot
-
Prevents shorting at bottom of plate
-
Boot and c-wrap fully insulate plate
Deep Well Support Bridge
-
Allows plate growth without affecting performance
-
Increases the life of battery
-
Reduces stress on Jar-to-Cover and Post seals
-
Supports the element in horizontal position
Patented Ribbed Jar Design
-
Provides extra strength
-
Provides space-effiicient airflow gap for uniform
cell temperatures
-
Better heat dissipation optimizes cell life
-
Five times more tolerant against thermal runway
effects than non-ribbed designs
C-Wrap AGM
-
Prevents plates from shorting on the side and edges
-
Extra thick and absorbent mats for long life
Patent Positive Grid Design
-
Proprietary grid design reduces plate growth
-
Excellent cycling capability of 1200 cycles at 80%
DOD to 1.75 Vpc at 77F
-
Thick lead-calcium-tin positive plate-0.240 inches
(6 mm) for 20-year design life
Proven Jar-to-Cover Seal
-
Six times more reliable than most seal designs
-
Tested to be leak free for over 20 years
-
All cells 100% factory tested
-
Ensures maximum product reliability
|
PVC Jar and Cover
-
Prevents premature dry-out
-
Lowest combination of oxygen and water transmission
rate
-
Meets ASTM D-635, UL-94-VO, 32% LOI standard
Redundant Post Seal Design
-
Patented bonding process adheres lead to rubber
bushing and rubber to PVC
-
Provides leak-free operation
Threaded Copper Inserted Post
-
Reduces resistance
-
Improves high rate performance
-
High torque limit 160 lbs
Moss Shield
-
Prevents premature shorting, extending usable
battery life
Computer-Controlled Heliarc Weld
-
High quality consistent weld
-
100% tested for maximum reliability
-
Provides leak-free operation
Largest Post Design
-
Lower post resistance
-
Large area for easy access by test equipment
Tetrabasic Lead Sulfate
-
Patented C&D paste formula provides large
interlocking crystals for longer life
-
Also used in "Roundcell"
|
Exclusive and Patented Module
Pressure Plate Design
-
Provides
optimum cell performance
- Easy removal and installation of cells
- Front or side access available
Modular Steel Tray
-
Meets Zone 4 seismic requirements stacked eight high
-
Easy to install and assemble
Tin-Plated Intercell Connectors
Clear Safety Shields
- Enables visual inspection of cells and
connections without removal
|
The Maximizer™ Makes the Best VRLA Battery Even Better
|
 |
The
Maximizer is the patented cap system that reduces
corrosion of the positive grids, maintains a properly
charged negative plate, and virtually eliminates
dry-out. The Maximixer also:
-
Reduces float current
-
Maintains cell capacity
-
Creates lower impedance
-
Saves you money (with its lower current and longer
useful life)
|
Excess oxygen is attracted to the Maximizer and
prevented from affecting the negative plate
potential.
|
CELL SPECIFICATIONS
|
Product
model number
|
Positive
plates
|
Width
in (mm)
|
Depth
in (mm)
|
Height
in (mm)
|
Weight
lbs (kgs)
|
Electrolyte
specific gravity
|
Float
voltage
|
RHD-190
RHDL-160 |
3
|
3.0 (76.2)
|
15.44 (392.2)
|
8.9 (226.1)
|
40
(18)
|
1.300 RHD/
1.250 RHDL
|
2.25-2.27 Vpc
at 77F (25C) RHD/
2.19-2.21 Vpc
at 77F (25C) RHDL
|
RHD-250
RHDL-215 |
4
|
3.8 (96.5)
|
50
(23)
|
RHD-315
RHDL-270 |
5
|
4.5 (114.3)
|
61
(28)
|
RHD-440
RHDL-375 |
7
|
5.9 (149.9)
|
83
(38)
|
RHD-600
RHDL-500 |
9
|
7.4 (188.0)
|
104
(47)
|
|
Product
model number
|
Positive
plates
|
Width
in (mm)
|
Depth
in (mm)
|
Height
in (mm)
|
Weight
lbs (kgs)
|
Electrolyte
specific gravity
|
Float
voltage
|
HD-300
HDL-260 |
3
|
3.0
(76.2)
|
23.13
(587.5)
|
8.9
(226.1)
|
55
(25)
|
1.300 HD/
1.250 HDL
|
2.25-2.27 Vpc
at 77F (25C) HD/
2.19-2.21 Vpc
at 77F (25C) HDL
|
HD-400
HDL-350 |
4
|
3.8
(96.5)
|
80
(36)
|
HD-500
HDL-440 |
5
|
4.5
(114.3)
|
98
(45)
|
HD-700
HDL-610 |
7
|
5.9
(149.9)
|
132
(60)
|
HD-900
HDL-785 |
9
|
7.4
(188.0)
|
166
(75)
|
HD-1100
HDL-960 |
11
|
8.9
(226.0)
|
200
(91)
|
HD-1300
HDL-1135 |
13
|
10.3
(261.6)
|
237
(108)
|
|
NOTE: |
RHDL and HDL cells are designed with 1.250 specific
gravity acid for low float voltage applications or
parallel operation with flooded cells.
|
MODULE
SPECIFICATIONS
Module
building blocks |
Number
of cells |
Volts |
8-Hour capacity
(ampere-hours) |
Width
in
(mm) |
Height*
in
(mm) |
Depth**
in
(mm) |
Weight
lbs
(kgs) |
|
6-RHD-190†
|
6 |
12 |
200 |
21.2 (538) |
9.9
(251.5) |
16.95 (430.5) |
310
(141) |
|
6-RHDL-160†
|
170 |
|
4-RHD-250†
|
4 |
8 |
260 |
18.3 (465) |
262
(119) |
|
4-RHDL-215†
|
225 |
|
6-RHD-250
|
6 |
12 |
260 |
25.9 (658) |
385
(175) |
|
6-RHDL-215
|
225 |
|
4-RHD-315†
|
4 |
8 |
330 |
21.2 (538) |
307
(140) |
|
4-RHDL-270†
|
280 |
|
6-RHD-315
|
6 |
12 |
330 |
30.2 (767) |
455
(207) |
|
6-RHDL-270
|
280 |
|
3-RHD-440†
|
3 |
6 |
460 |
21.2 (538) |
309
(140) |
|
4-RHDL-375†
|
390 |
|
4-RHD-440
|
4 |
8 |
460 |
27.0 (686) |
408
(185) |
|
4-RHDL-375
|
390 |
|
6-RHD-440
|
6 |
12 |
460 |
39.0 (991) |
602
(274) |
|
6-RHDL-375
|
390 |
|
3-RHD-600
|
3 |
6 |
600 |
25.9 (658) |
379
(172) |
|
3-RHDL-500
|
495 |
|
4-RHD-600
|
4 |
8 |
600 |
32.9 (836) |
502
(228) |
|
4-RHDL-500 |
495 |
|
Module
building blocks
|
Number
of cells
|
Volts
|
8-Hour capacity
(ampere-hours)
|
Width
in (mm)
|
Height*
in (mm)
|
Depth**
in (mm)
|
Weight
lbs (kgs)
|
|
6-HD-300†
|
6
|
12
|
330 |
21.4 (544) |
9.9
(251.5) |
25.5 (647.7) |
425
(193) |
|
6-HDL-260†
|
275 |
|
4-HD-400†
|
4
|
8
|
440 |
18.5 (470) |
398
(181) |
|
4-HDL-350†
|
370 |
|
6-HD-400
|
6
|
12
|
440 |
26.1 (663) |
582
(265) |
|
6-HDL-350
|
370 |
|
4-HD-500†
|
4
|
8
|
550 |
21.4 (544) |
474
(215) |
|
4-HDL-440†
|
460 |
|
6-HD-500
|
6
|
12
|
550 |
30.4 (772) |
700
(318) |
|
6-HDL-440
|
460 |
|
3-HD-700†
|
3
|
6
|
770 |
21.4 (544) |
475
(216) |
|
3-HDL-610†
|
640 |
|
4-HD-700
|
4
|
8
|
770 |
27.3 (693) |
622
(283) |
|
4-HDL-610
|
640 |
|
6-HD-700
|
6
|
12
|
770 |
39.3 (998) |
920
(418) |
|
6-HDL-610
|
640 |
|
3-HD-900
|
3
|
6
|
990 |
26.1 (663) |
585
(266) |
|
3-HDL-785
|
825 |
|
4-HD-900
|
4
|
8
|
990 |
33.2 (843) |
768
(349) |
|
4-HDL-785
|
825 |
|
3-HD-1100
|
3
|
6
|
1210 |
30.4 (772) |
688
(313) |
|
3-HDL-960
|
1010 |
|
4-HD-1100
|
4
|
8
|
1210 |
39.3 (998) |
915
(416) |
|
4-HDL-960
|
1010 |
|
3-HD-1300
|
3
|
6
|
1430 |
34.4 (874) |
815
(370) |
|
3-HDL-1135
|
1190 |
|
4-HD-1300††
|
4
|
8
|
1430 |
45.5 (1156) |
1032 (469) |
|
4-HDL-1135††
|
1190 |
For
ampere rates see publication 12-371-AMP
For kilowatt rates see publication 12-371-KW
For RHDL-HDL see publication 12-376 |
|
Note: All ratings conform to IEEE-485. 1997 |
|
*Add 4.9 inches (125 mm)
for HD/HDL, or 4.4 inches (112
mm) for RHD/RHDL, to the height of the base
support, for total stack height. |
|
The
base support weight ranges from 34 lbs
(15.3 kgs) to 55 lbs (25
kgs) depending on width. A reduced height
(2.5 inches tall) base is available as an
option. |
|
**Total depth includes clear faceplates over terminal
connections. Subtract 1/2 inch
(12.7 mm) without faceplates. |
|
†These modules can be installed in a 23-inch relay
rack. Allow 4 inches (102 mm),
the height of the rack base, for the total stack
height. |
|
††Stack height is limited to six modules for seismic
zone 4. |
|
Design a system using these standards building
blocks. You can:
-
Steel Module
-
Pressure plate
-
Pressure plate adjustment bolts
-
Cell spacer plate
-
Cells
|
UNIQUE MODULAR DESIGN STACK SYSTEM
(patent pending)
-
Integrated module system exceeds 1994 UBC Zone 4
requirements
-
Provides thermal management of cells
-
Allows simple, quick installation and removal of
cells
-
Provides consistent compression of cells
-
Provides airflow channels between cells
|
|
MOUNTING AND TERMINATING CHOICES
|
STANDARD TERMINATION
Low Profile Mounting
Modules stacked on optional low profile base (shown
with protective faceplates and optional front access
cam system)

|
TOP TERMINATION
Standard Mounting
Modules stacked on standard height base module
(shown with protective faceplate removed)

|
|